品牌:RETZ瑞茨/美国,我们一直致力于流体控制领域的持续创新,始于2005……
功能:当阀前压力有波动或流量变化的情况下,它能使管道内的高压水自动地减为稳定的低压水,而且减压阀的出口压力在一定范围内可随意调节Function: In the event of pressure fluctuations or flow changes in front of the valve, it can automatically reduce the high-pressure water in the pipeline to stable low-pressure water, and the outlet pressure of the pressure reducing valve can be adjusted freely within a certain range
进口水减压阀产品详情 Product details
水减压阀(水力调节阀)控制主阀的固定出口压力,不因主阀上游进口压力变化而改变,亦不因主阀下游出口用水量变化而改变其出口压力。可用于生活给水、消防系统及工业给水系统
The water pressure reducing valve (hydraulic regulating valve) controls the fixed outlet pressure of the main valve and does not change due to changes in the upstream inlet pressure of the main valve, nor does it change its outlet pressure due to changes in the downstream outlet water consumption of the main valve. Can be used for domestic water supply, fire protection systems, and industrial water supply systems
进口水减压阀工作原理 Working principle
当阀门从进口端给水时,水流过针阀进入主阀控制室,出口压力通过导管作用到导阀上。 当出口压力高于导阀弹簧设定值时,导阀关闭。控制室停止排水,此时主阀控制室内压力升高并关闭主阀,出口压力不再升高。当阀门出口压力降到导阀弹簧设定压力时,导阀开启,控制室向下游排水。由于导阀系统排水量大于针阀的进水量,主阀控制室压力下降。进口压力使主阀开启。在稳定状态下,控制室进水、排水相同,主阀开度不变,出口压力稳定。调节导阀弹簧即可设定出口压力。
结构特点 Structural characteristics
水力控制,无需外部驱动力;
主阀只有一个运动部件,故障率低;
隔膜式结构,无摩擦,控制灵敏度高,压力特性不大于 5%,流量特性不大于 10%;
阀后压力可设定,不随流量和阀前压力的改变而变化;
可减静压;
A200 系列可调式减压阀适合于汽蚀系数不小于 0.5 的场合;
当汽蚀系数小于 0.5, 大于 0.2 的场合,可选择 A202 系列高性能可调式减压阀。
技术参数:
公称通径:DN50~DN600
公称压力:PN16、N25
适用温度:0℃~80℃
适用介质:清水
压力等级:PN10(调节范围0.1-0.8Mpa)
PN16(调节范围0.2-1.4Mpa)
PN25(调节范围0.3-2.0Mpa)
***小压差:0.1MPa
液面控制高度:≤150mm
阀体材质:球墨铸铁、碳钢、不锈钢
膜片材质:丁腈尼龙强化橡胶、三元乙丙尼龙强化橡胶