品牌:RETZ瑞茨/美国,我们一直致力于流体控制领域的持续创新,始于2005……
功能:用于住宅小区中的消防与生活用水合并的供水系统,当消防系统启动时,压力升高时,自动切断生活用水,保证消防供水的压力
Function: Used as a water supply system for merging fire and domestic water in residential communities. When the fire protection system starts and the pressure increases, it automatically cuts off domestic water to ensure the pressure of fire water supply
产品详情 Product details
紧急关闭阀、高压自闭阀利用水作用力自动控制阀门的关闭和开启的阀门,通常用在消防与生活共用并联的供水系统中。当消防系统启动时,管道压力升高,超过设定值时,能自动关闭生产
Emergency shut-off valves and high-pressure self closing valves are valves that use water force to automatically control the closing and opening of valves. They are usually used in parallel water supply systems shared by firefighting and daily life. When the fire protection system starts, the pipeline pressure increases, and when it exceeds the set value, it can automatically shut down production
进口紧急关闭阀工作原理 Working principle
1.导阀膜片下腔连接到主阀进口,可以反馈到进口压力大小。松开导阀防松螺母,顺时针转动导阀调节螺钉,调节弹簧被压缩,在工作原理.jpg弹簧作用力下,导阀芯开启。主阀膜片上腔内水流出,压力降低,在主阀膜片上下腔压力差作用下,主阀开启。开始供水
2.当消防供水时,进口压力上升(消防时用水量大,压力也高)导阀膜片下腔压力上升,带动导阀芯关闭。主阀膜片上腔内水无法排除,压力上升。在主阀膜片上下腔压力差作用下,主阀关闭。停止供水。这时所有供水通过消防管道流出,居民生活供水停止,保证了消防用水需求
3.停止消防供水后,进口压力下降。导阀膜片下腔压力也下降,在导阀弹簧力作用下,导阀芯开启。主阀膜片上腔内水流出,压力下降,在主阀膜片上下腔压力差作用下,主阀重新开启供水,保证生产或生活用水需求
进口紧急关闭阀技术规范 Technical specifications
公称通径:DN50~DN500
适用温度:0℃~100℃
***小压差:0.1MPa
液面控制高度:≤150mm
公称压力:PN10-25
阀体材质:球墨铸铁、碳钢、不锈钢
膜片材质:丁腈尼龙强化橡胶、三元乙丙尼龙强化橡胶